New to the HP Array Configuration Utility?  Me too, so I did some Googling and found an awesome cheat sheet.  I don’t want to steal any credit from its original authors, but I do think it should be reposted for archival.  I’d like a copy of it for my own reference, so I decided to toss it here on Binary Impulse so others might stumble across it.

Here’s the original article: http://www.datadisk.co.uk/html_docs/redhat/hpacucli.htm

Utility Keyword abbreviations
Abbreviations chassisname = ch
controller = ctrl
logicaldrive = ld
physicaldrive = pd
drivewritecache = dwc
hpacucli utility
hpacucli # hpacucli 

# hpacucli help

Note: you can use the hpacucli command in a script

Controller Commands
Display (detailed) hpacucli> ctrl all show config
hpacucli> ctrl all show config detail
Status hpacucli> ctrl all show status
Cache hpacucli> ctrl slot=0 modify dwc=disable
hpacucli> ctrl slot=0 modify dwc=enable
Rescan hpacucli> rescan 

Note: detects newly added devices since the last rescan

Physical Drive Commands
Display (detailed) hpacucli> ctrl slot=0 pd all show
hpacucli> ctrl slot=0 pd 2:3 show detail 

Note: you can obtain the slot number by displaying the controller configuration (see above)

Status hpacucli> ctrl slot=0 pd all show status
hpacucli> ctrl slot=0 pd 2:3 show status
Erase hpacucli> ctrl slot=0 pd 2:3 modify erase
Blink disk LED hpacucli> ctrl slot=0 pd 2:3 modify led=on
hpacucli> ctrl slot=0 pd 2:3 modify led=off
Logical Drive Commands
Display (detailed) hpacucli> ctrl slot=0 ld all show [detail]
hpacucli> ctrl slot=0 ld 4 show [detail]
Status hpacucli> ctrl slot=0 ld all show status
hpacucli> ctrl slot=0 ld 4 show status
Blink disk LED hpacucli> ctrl slot=0 ld 4 modify led=on
hpacucli> ctrl slot=0 ld 4 modify led=off
re-enabling failed drive hpacucli> ctrl slot=0 ld 4 modify reenable forced
Create # logical drive – one disk
hpacucli> ctrl slot=0 create type=ld drives=1:12 raid=0 

# logical drive – mirrored
hpacucli> ctrl slot=0 create type=ld drives=1:13,1:14 size=300 raid=1

# logical drive – raid 5
hpacucli> ctrl slot=0 create type=ld drives=1:13,1:14,1:15,1:16,1:17 raid=5

Note:
drives – specific drives, all drives or unassigned drives
size – size of the logical drive in MB
raid – type of raid 0, 1 , 1+0 and 5

Remove hpacucli> ctrl slot=0 ld 4 delete
Expanding hpacucli> ctrl slot=0 ld 4 add drives=2:3
Extending hpacucli> ctrl slot=0 ld 4 modify size=500 forced
Spare hpacucli> ctrl slot=0 array all add spares=1:5,1:7
Display (detailed) hpacucli> ctrl all show config
hpacucli> ctrl all show config detail
Status hpacucli> ctrl all show status
Cache hpacucli> ctrl slot=0 modify dwc=disable
hpacucli> ctrl slot=0 modify dwc=enable
Rescan hpacucli> rescan 

Note: detects newly added devices since the last rescan

3 Thoughts on “HP Array Configuration Utility Command Cheat Sheet

  1. hi… how to print out details in HPSSA? already tried | out-file but it didnt work.

    • Avatar photo Kirk Schnable on October 31, 2016 at 12:13 PM said:

      I believe HPSAA is different than HPACUCLI. The HPACUCLI utility is being deprecated.

      What command are you running and what is the issue with the out file?

  2. Thank you For your list of commands. Very useful.

Leave a Reply

Your email address will not be published. Required fields are marked *

Are you an intelligent human being? * Time limit is exhausted. Please reload CAPTCHA.

Post Navigation